Skip navigation
All Places > All Things PI - Ask, Discuss, Connect > Ideas

Add support for multiple events with same timestamp in PI Integrator for BA

score 15
You have not voted Submitted
Originally posted on UserVoice

The Integrator for BA appears to be a great fit for exporting event-based data such as Batch Interface Messages to external systems. Interpolation doesn’t apply in these cases so we can use a tag as the ‘Key’ in value mode selection.
However, there are cases where a tag can have multiple entries at a given timestamp (e.g. EMDVB Recipe Parameter Downloads) and the current behavior is to only include the first value in the output view. This approach results in missing data and makes the integrator unusable in these cases.
Ideally the view would return all records (as per PI OLEDB) or provide a selection to allow the user decide how it should behave